YYGL45MR | OEM / ODM / Distributor Supply
YYGL45MR combines RF receiver control with crank operation for power-failure use. It is suited to shutters and awnings where both remote control and emergency manual operation are required.
Product Images
YYGL45MR Product View and Application Context
Product photos are used for model recognition only. Final dimensions, tube cutting and bracket positions should be confirmed by drawing.



Quick Decision Table
Best For / Not Recommended For
Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.
Best For
- Roller shutters requiring RF remote control
- Awnings requiring crank operation during power failure
- Projects comparing YYGL45M vs YYGL45MR
- OEM systems needing manual override and receiver in one motor
Not Recommended For
- Systems without crank access
- Projects requiring electronic limit as the core feature
- Small narrow blinds
- Unsupported smart-home integration without compatible gateway
Model Positioning
Why Choose YYGL45MR
45mm mechanical limit motor with built-in receiver and manual override.
| Model | Positioning | When to Choose |
|---|---|---|
| YYGL45S | Standard mechanical limit | Mainstream 45mm wired AC projects. |
| YYGL45R | Mechanical limit with built-in receiver | RF remote control is required inside the motor head. |
| YYGL45B | Parallel electronic limit platform | External controller or supported parallel-control projects. |
| YYGL45E | Electronic limit with receiver | Electronic end-position setting and receiver control are required. |
| YYGL45M | Mechanical limit with manual override | Crank operation during power failure is required. |
| YYGL45MR | Manual override plus receiver | RF remote control plus emergency crank operation. |
| YYGL45SD | Short body design | Limited width with 45mm tube systems. |
| WM45DS | DC / solar battery solution | Use when low-voltage or solar configuration is confirmed. |
Core Procurement Parameters
YYGL45MR Purchasing Specification Summary
Use this section to check the model’s main procurement boundaries before preparing an RFQ.
| Parameter | Specification / Confirmation Note |
|---|---|
| Motor diameter | 45mm |
| Torque range | 20-50Nm |
| Rated voltage | 230V AC |
| Frequency | 50Hz |
| Limit system | Built-in receiver + manual override |
| Control method | Built-in RF receiver / compatible transmitter |
| Protection rating | IP44 |
| Application | Roller shutters and awnings needing RF control plus crank operation |
| OEM options | Voltage, cable length, plug, motor head, label, packaging and matched accessories by order requirement |
| Accessory matching requirement | Tube, crown adaptor, drive wheel and bracket must be checked by drawing or sample |
| Certification document availability | Available by exact model, voltage and destination market confirmation |
Engineering Parameters by Torque Version
YYGL45MR Technical Data Table
The following values use the model data supplied for this upgrade. Garbled legacy values have been separated into protection, limit type and total length where applicable.
| Model | Torque | Rated speed | Voltage | Frequency | Rated power | Rated current | Running time | Protection | Limit turns | Total length |
|---|---|---|---|---|---|---|---|---|---|---|
| YYGL45MR-20/15 | 20Nm | 15rpm | 230V | 50Hz | 156W | 0.68A | 4 minutes | IP44 | 22 | 640mm |
| YYGL45MR-30/15 | 30Nm | 15rpm | 230V | 50Hz | 204W | 0.90A | 4 minutes | IP44 | 22 | 680mm |
| YYGL45MR-40/15 | 40Nm | 15rpm | 230V | 50Hz | 218W | 0.95A | 4 minutes | IP44 | 22 | 720mm |
| YYGL45MR-50/12 | 50Nm | 12rpm | 230V | 50Hz | 232W | 1.01A | 4 minutes | IP44 | 22 | 720mm |
Mechanical Data
Tube, Head and Accessory Requirements
Confirm 60mm / 70mm tube matching, bracket alignment, manual crank access angle, drive wheel and crown adaptor before approving installation design.
| Item | Engineering Note |
|---|---|
| Motor diameter | 45mm |
| Total length | See engineering table by torque version |
| Tube compatibility | Common 60mm / 70mm octagonal tubes when matched with the correct accessories. |
| Crown adaptor | Match crown profile to tube shape and inner diameter |
| Drive wheel | Confirm drive wheel profile, torque transfer and insertion depth |
| Bracket | Confirm motor head, fixing holes, load direction and site structure |
| Cable length | Standard or OEM length available on request |
| Motor head | Confirm head style, receiver/manual override clearance and bracket fit |
| Accessory notes | Confirm 60mm / 70mm tube matching, bracket alignment, manual crank access angle, drive wheel and crown adaptor before approving installation design. |
Dimension and Installation Information
Request Drawing Before Final Installation Design
Check manual override head length, crank access direction and bracket clearance from the dimension drawing before finalizing system width.
Do not finalize tube cutting, bracket position, minimum system width or installation clearance from product photos alone. Share the tube drawing, bracket structure and application size for confirmation.

Tube, Crown, Drive Wheel and Bracket Matching
Compatibility Must Be Confirmed as a System
Motor selection is only one part of the system. Real performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and installation quality.
| System Part | Compatibility Check |
|---|---|
| Tube diameter | Confirm 60mm / 70mm octagonal or special tube profile. |
| Crown adaptor | Must match tube profile; do not assume one crown fits all tubes. |
| Drive wheel | Must match torque, tube profile and insertion depth. |
| Bracket | Check head style, fixing hole, load direction and installation alignment. |
| Controller / receiver | Confirm wiring, transmitter, gateway or controller compatibility when applicable. |
| Installation quality | Motor performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and side-guide friction. |
Related resources: Accessories and tube and bracket compatibility guide.
Wiring / Control / Limit Setting Notes
Confirm Control Configuration Before Installation
YYGL45MR uses a built-in RF receiver with mechanical limit setting and manual override. Use compatible transmitters and confirm gateway or smart integration by selected controller.
Safety note: Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring. Ask Walter Motor for the correct wiring diagram before bulk installation.
Compare limit and control choices in the limit systems guide and manual override guide.
Application Review
Where YYGL45MR Fits
Application fit must be checked together with load, tube, control method, environment and duty cycle.
| Application | Fit | Engineering Check |
|---|---|---|
| Roller blinds | Yes | Confirm tube diameter, fabric weight and minimum width. |
| Roller shutters | Yes | Confirm shutter weight, side guide friction and duty cycle. |
| Zip screens | Possible | Check fabric tension, guide friction and controller requirement. |
| Awnings | Possible | Confirm arm load, wind exposure and torque margin. |
| Garage doors / heavy shutters | Not standard | Requires project-specific safety devices and local compliance review. |
| Fire shutters | Not standard | Do not select without project-specific certification and safety validation. |
| Manual crank operation | Yes | Confirm crank access, bracket and head direction. |
| Electronic limit setting | Not standard | Choose electronic limit model if electronic setting is required. |
Torque Selection Guidance
Do Not Select Torque by Curtain Weight Alone
Torque selection should include curtain or fabric weight, tube diameter, lifting radius, side-guide friction, arm system or fabric tension, operating frequency, safety factor and installation environment.
Curtain or fabric weight
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Tube diameter and lifting radius
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Side guide friction
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Arm system or fabric tension
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Operating frequency
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Safety factor
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Installation environment
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Destination market requirement
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Related guide: torque calculation for tubular motors.
OEM / ODM Options
Configuration Options for Project Buyers
Walter Motor can discuss OEM options according to target quantity, destination market and certification requirement.
Customization reference: OEM / ODM customization.
Quality Control
Quality Control for YYGL45MR Series
Walter Motor controls production through incoming material inspection, stator winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.








See production process and quality control for factory-level context.
Certifications and Compliance
Certificate Coverage Must Match Exact Model and Market
Walter Motor can provide certification documents according to exact model, voltage and destination market. Commonly requested documents may include CE, LVD, EMC, RoHS and related reports. Certificate coverage must be confirmed by exact model and market.
Technical Document Request
Request Technical Documents
If PDF files are not published, these requests go to Walter Motor technical support instead of pretending to be direct downloads.
FAQ
YYGL45MR Buyer Questions
What is YYGL45MR best used for?
YYGL45MR Manual Override Receiver Motor is best used for roller shutters and awnings needing rf control plus crank operation after torque, tube and accessory matching are confirmed.
How is YYGL45MR different from YYGL45S?
YYGL45MR is positioned as a 45mm receiver motor with manual override. Compare nearby models when receiver, electronic limit, short body or manual override functions are required.
What control method does YYGL45MR use?
Built-in RF receiver / compatible transmitter. Where smart integration is required, confirm the compatible gateway or controller before ordering.
Which tube is compatible with YYGL45MR?
Common 60mm / 70mm octagonal tubes may be used when the crown adaptor, drive wheel and bracket match the tube.
How should torque be selected for YYGL45MR?
Do not select torque by curtain weight alone. Confirm curtain size, weight, tube diameter, lifting radius, guide friction, duty cycle and safety factor.
Does YYGL45MR include manual override?
Yes. Manual override is part of this model's positioning, but crank access, bracket and head direction must be confirmed.
Does YYGL45MR include electronic limit or built-in receiver?
No. It uses mechanical limit setting unless a different selected variant is confirmed. Yes. Receiver control is part of this model positioning and requires compatible Walter transmitters or a confirmed controller.
Can Walter Motor provide certificates and OEM options for YYGL45MR?
Walter Motor can provide certificate coverage checks and OEM options according to exact model, voltage, control configuration, quantity and destination market.
RFQ Checklist
Information to Send Before Quotation
Complete information helps Walter Motor check torque, tube compatibility, control method and OEM configuration before sample or batch order.
Technical Support
Need help confirming YYGL45MR compatibility?
Send your tube drawing, curtain size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.

