Zhejiang Walter Tubular Motor supplier

YYGL45MR 45mm Receiver Manual Override Motor for Shutters and Awnings

YYGL45MR | OEM / ODM / Distributor Supply

YYGL45MR 45mm Receiver Manual Override Motor for Shutters and Awnings

YYGL45MR combines RF receiver control with crank operation for power-failure use. It is suited to shutters and awnings where both remote control and emergency manual operation are required.

ModelYYGL45MR
Diameter45mm
Torque range20-50Nm
Speed range12-15rpm
Rated voltage230V AC / 50Hz
Limit systemBuilt-in receiver + manual override
Control methodBuilt-in RF receiver / compatible transmitter
ProtectionIP44
Best applicationRoller shutters and awnings needing RF control plus crank operation
YYGL45MR 45mm receiver manual override motor
YYGL45MR 45mm receiver manual override motor.

Product Images

YYGL45MR Product View and Application Context

Product photos are used for model recognition only. Final dimensions, tube cutting and bracket positions should be confirmed by drawing.

Quick Decision Table

Best For / Not Recommended For

Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.

Best For

  • Roller shutters requiring RF remote control
  • Awnings requiring crank operation during power failure
  • Projects comparing YYGL45M vs YYGL45MR
  • OEM systems needing manual override and receiver in one motor

Not Recommended For

  • Systems without crank access
  • Projects requiring electronic limit as the core feature
  • Small narrow blinds
  • Unsupported smart-home integration without compatible gateway

Model Positioning

Why Choose YYGL45MR

45mm mechanical limit motor with built-in receiver and manual override.

45mm same series comparison
ModelPositioningWhen to Choose
YYGL45SStandard mechanical limitMainstream 45mm wired AC projects.
YYGL45RMechanical limit with built-in receiverRF remote control is required inside the motor head.
YYGL45BParallel electronic limit platformExternal controller or supported parallel-control projects.
YYGL45EElectronic limit with receiverElectronic end-position setting and receiver control are required.
YYGL45MMechanical limit with manual overrideCrank operation during power failure is required.
YYGL45MRManual override plus receiverRF remote control plus emergency crank operation.
YYGL45SDShort body designLimited width with 45mm tube systems.
WM45DSDC / solar battery solutionUse when low-voltage or solar configuration is confirmed.

Core Procurement Parameters

YYGL45MR Purchasing Specification Summary

Use this section to check the model’s main procurement boundaries before preparing an RFQ.

YYGL45MR core procurement parameters
ParameterSpecification / Confirmation Note
Motor diameter45mm
Torque range20-50Nm
Rated voltage230V AC
Frequency50Hz
Limit systemBuilt-in receiver + manual override
Control methodBuilt-in RF receiver / compatible transmitter
Protection ratingIP44
ApplicationRoller shutters and awnings needing RF control plus crank operation
OEM optionsVoltage, cable length, plug, motor head, label, packaging and matched accessories by order requirement
Accessory matching requirementTube, crown adaptor, drive wheel and bracket must be checked by drawing or sample
Certification document availabilityAvailable by exact model, voltage and destination market confirmation

Engineering Parameters by Torque Version

YYGL45MR Technical Data Table

The following values use the model data supplied for this upgrade. Garbled legacy values have been separated into protection, limit type and total length where applicable.

YYGL45MR electrical and mechanical data
ModelTorqueRated speedVoltageFrequencyRated powerRated currentRunning timeProtectionLimit turnsTotal length
YYGL45MR-20/1520Nm15rpm230V50Hz156W0.68A4 minutesIP4422640mm
YYGL45MR-30/1530Nm15rpm230V50Hz204W0.90A4 minutesIP4422680mm
YYGL45MR-40/1540Nm15rpm230V50Hz218W0.95A4 minutesIP4422720mm
YYGL45MR-50/1250Nm12rpm230V50Hz232W1.01A4 minutesIP4422720mm

Mechanical Data

Tube, Head and Accessory Requirements

Confirm 60mm / 70mm tube matching, bracket alignment, manual crank access angle, drive wheel and crown adaptor before approving installation design.

YYGL45MR mechanical data
ItemEngineering Note
Motor diameter45mm
Total lengthSee engineering table by torque version
Tube compatibilityCommon 60mm / 70mm octagonal tubes when matched with the correct accessories.
Crown adaptorMatch crown profile to tube shape and inner diameter
Drive wheelConfirm drive wheel profile, torque transfer and insertion depth
BracketConfirm motor head, fixing holes, load direction and site structure
Cable lengthStandard or OEM length available on request
Motor headConfirm head style, receiver/manual override clearance and bracket fit
Accessory notesConfirm 60mm / 70mm tube matching, bracket alignment, manual crank access angle, drive wheel and crown adaptor before approving installation design.

Dimension and Installation Information

Request Drawing Before Final Installation Design

Check manual override head length, crank access direction and bracket clearance from the dimension drawing before finalizing system width.

Do not finalize tube cutting, bracket position, minimum system width or installation clearance from product photos alone. Share the tube drawing, bracket structure and application size for confirmation.

Total lengthCheck by torque version
Tube insertionConfirm by crown and drive wheel
Bracket positionConfirm by head and load direction
Cable / control clearanceConfirm before sample order
YYGL45MR dimension drawing for installation confirmation
YYGL45MR dimension drawing for reference; request the latest drawing before final design.

Tube, Crown, Drive Wheel and Bracket Matching

Compatibility Must Be Confirmed as a System

Motor selection is only one part of the system. Real performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and installation quality.

YYGL45MR compatibility checklist
System PartCompatibility Check
Tube diameterConfirm 60mm / 70mm octagonal or special tube profile.
Crown adaptorMust match tube profile; do not assume one crown fits all tubes.
Drive wheelMust match torque, tube profile and insertion depth.
BracketCheck head style, fixing hole, load direction and installation alignment.
Controller / receiverConfirm wiring, transmitter, gateway or controller compatibility when applicable.
Installation qualityMotor performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and side-guide friction.

Related resources: Accessories and tube and bracket compatibility guide.

Wiring / Control / Limit Setting Notes

Confirm Control Configuration Before Installation

YYGL45MR uses a built-in RF receiver with mechanical limit setting and manual override. Use compatible transmitters and confirm gateway or smart integration by selected controller.

YYGL45M vs YYGL45MR: YYGL45M is the manual override model for wired or external receiver control. YYGL45MR adds a built-in receiver for RF remote control while keeping the manual crank function.

Safety note: Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring. Ask Walter Motor for the correct wiring diagram before bulk installation.

Compare limit and control choices in the limit systems guide and manual override guide.

Application Review

Where YYGL45MR Fits

Application fit must be checked together with load, tube, control method, environment and duty cycle.

YYGL45MR application review
ApplicationFitEngineering Check
Roller blindsYesConfirm tube diameter, fabric weight and minimum width.
Roller shuttersYesConfirm shutter weight, side guide friction and duty cycle.
Zip screensPossibleCheck fabric tension, guide friction and controller requirement.
AwningsPossibleConfirm arm load, wind exposure and torque margin.
Garage doors / heavy shuttersNot standardRequires project-specific safety devices and local compliance review.
Fire shuttersNot standardDo not select without project-specific certification and safety validation.
Manual crank operationYesConfirm crank access, bracket and head direction.
Electronic limit settingNot standardChoose electronic limit model if electronic setting is required.

Torque Selection Guidance

Do Not Select Torque by Curtain Weight Alone

Torque selection should include curtain or fabric weight, tube diameter, lifting radius, side-guide friction, arm system or fabric tension, operating frequency, safety factor and installation environment.

Curtain or fabric weight

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Tube diameter and lifting radius

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Side guide friction

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Arm system or fabric tension

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Operating frequency

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Safety factor

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Installation environment

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Destination market requirement

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Related guide: torque calculation for tubular motors.

OEM / ODM Options

Configuration Options for Project Buyers

Walter Motor can discuss OEM options according to target quantity, destination market and certification requirement.

Voltage
Torque
Cable length
Plug / connector
Motor head
Label
Packaging
Crown adaptor
Drive wheel
Bracket
Remote / receiver / controller if applicable
Sample order
Batch production

Customization reference: OEM / ODM customization.

Quality Control

Quality Control for YYGL45MR Series

Walter Motor controls production through incoming material inspection, stator winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.

See production process and quality control for factory-level context.

Certifications and Compliance

Certificate Coverage Must Match Exact Model and Market

Walter Motor can provide certification documents according to exact model, voltage and destination market. Commonly requested documents may include CE, LVD, EMC, RoHS and related reports. Certificate coverage must be confirmed by exact model and market.

Request Certificate Coverage View certificate page

Technical Document Request

Request Technical Documents

If PDF files are not published, these requests go to Walter Motor technical support instead of pretending to be direct downloads.

FAQ

YYGL45MR Buyer Questions

What is YYGL45MR best used for?

YYGL45MR Manual Override Receiver Motor is best used for roller shutters and awnings needing rf control plus crank operation after torque, tube and accessory matching are confirmed.

How is YYGL45MR different from YYGL45S?

YYGL45MR is positioned as a 45mm receiver motor with manual override. Compare nearby models when receiver, electronic limit, short body or manual override functions are required.

What control method does YYGL45MR use?

Built-in RF receiver / compatible transmitter. Where smart integration is required, confirm the compatible gateway or controller before ordering.

Which tube is compatible with YYGL45MR?

Common 60mm / 70mm octagonal tubes may be used when the crown adaptor, drive wheel and bracket match the tube.

How should torque be selected for YYGL45MR?

Do not select torque by curtain weight alone. Confirm curtain size, weight, tube diameter, lifting radius, guide friction, duty cycle and safety factor.

Does YYGL45MR include manual override?

Yes. Manual override is part of this model's positioning, but crank access, bracket and head direction must be confirmed.

Does YYGL45MR include electronic limit or built-in receiver?

No. It uses mechanical limit setting unless a different selected variant is confirmed. Yes. Receiver control is part of this model positioning and requires compatible Walter transmitters or a confirmed controller.

Can Walter Motor provide certificates and OEM options for YYGL45MR?

Walter Motor can provide certificate coverage checks and OEM options according to exact model, voltage, control configuration, quantity and destination market.

RFQ Checklist

Information to Send Before Quotation

Complete information helps Walter Motor check torque, tube compatibility, control method and OEM configuration before sample or batch order.

Application
Curtain size
Curtain weight
Tube type and diameter
Required torque or current motor model
Voltage and frequency
Control method
Limit system
Cable length and plug
Accessory requirement
Target quantity
Destination market and certification requirement

Technical Support

Need help confirming YYGL45MR compatibility?

Send your tube drawing, curtain size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.