YYGL59S | OEM / ODM / Distributor Supply
YYGL59S is the heavy-duty mechanical limit model. It should not be described as standard obstacle detection, manual override or electronic limit. Choose YYGL59M or YYGL59MR for crank operation, and YYGL59E for electronic limit.
Product Images
YYGL59S Product View and Application Context
Product photos are used for model recognition only. Final dimensions, tube cutting and bracket positions should be confirmed by drawing.



Quick Decision Table
Best For / Not Recommended For
Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.
Best For
- Heavy roller shutters
- Commercial shutters
- Large awnings
- Heavy-duty shading systems
- Projects needing simple wired control or external receiver
Not Recommended For
- Standard manual override requirement
- Electronic limit requirement
- Standard obstacle detection claims
- Light blinds where smaller motors are sufficient
Model Positioning
Why Choose YYGL59S
59mm standard mechanical limit AC tubular motor for heavy roller shutters, commercial shutters, large awnings and heavy-duty shading systems.
| Model | Positioning | When to Choose |
|---|---|---|
| YYGL59S | Standard mechanical limit | Heavy shutters and large systems with wired control or external receiver. |
| YYGL59R | Mechanical limit with built-in receiver | Heavy systems needing RF receiver control. |
| YYGL59M | Manual override | Crank operation is required for heavy systems. |
| YYGL59MR | Manual override plus receiver | RF control and crank operation are both required. |
| YYGL59E | Electronic limit | Heavy systems needing electronic end-position setting. |
Core Procurement Parameters
YYGL59S Purchasing Specification Summary
Use this section to check the model’s main procurement boundaries before preparing an RFQ.
| Parameter | Specification / Confirmation Note |
|---|---|
| Motor diameter | 59mm |
| Torque range | 60-140Nm |
| Rated voltage | 230V AC |
| Frequency | 50Hz |
| Limit system | Mechanical limit switch |
| Control method | Wall switch / external receiver |
| Protection rating | IP44 |
| Application | Heavy roller shutters, commercial shutters and large awnings |
| OEM options | Voltage, cable length, plug, motor head, label, packaging and matched accessories by order requirement |
| Accessory matching requirement | Tube, crown adaptor, drive wheel and bracket must be checked by drawing or sample |
| Certification document availability | Available by exact model, voltage and destination market confirmation |
Engineering Parameters by Torque Version
YYGL59S Technical Data Table
The following values use the model data supplied for this upgrade. Garbled legacy values have been separated into protection, limit type and total length where applicable.
| Model | Torque | Rated speed | Voltage | Frequency | Rated power | Rated current | Running time | Protection | Limit turns | Total length |
|---|---|---|---|---|---|---|---|---|---|---|
| YYGL59S-60/15 | 60Nm | 15rpm | 230V | 50Hz | 310W | 1.35A | 4 minutes | IP44 | 22 | 600mm |
| YYGL59S-80/15 | 80Nm | 15rpm | 230V | 50Hz | 330W | 1.43A | 4 minutes | IP44 | 22 | 600mm |
| YYGL59S-100/12 | 100Nm | 12rpm | 230V | 50Hz | 350W | 1.52A | 4 minutes | IP44 | 22 | 600mm |
| YYGL59S-120/9 | 120Nm | 9rpm | 230V | 50Hz | 360W | 1.56A | 4 minutes | IP44 | 22 | 600mm |
| YYGL59S-140/9 | 140Nm | 9rpm | 230V | 50Hz | 430W | 1.86A | 4 minutes | IP44 | 22 | 600mm |
Mechanical Data
Tube, Head and Accessory Requirements
Heavy-duty tube, crown, drive wheel and bracket matching must be confirmed by 70mm+ tube drawing or sample. Accessory strength and bracket alignment affect real performance.
| Item | Engineering Note |
|---|---|
| Motor diameter | 59mm |
| Total length | See engineering table by torque version |
| Tube compatibility | Heavy-duty 70mm+ tube systems; confirm tube profile and accessory strength. |
| Crown adaptor | Match crown profile to tube shape and inner diameter |
| Drive wheel | Confirm drive wheel profile, torque transfer and insertion depth |
| Bracket | Confirm motor head, fixing holes, load direction and site structure |
| Cable length | Standard or OEM length available on request |
| Motor head | Confirm head style, receiver/manual override clearance and bracket fit |
| Accessory notes | Heavy-duty tube, crown, drive wheel and bracket matching must be confirmed by 70mm+ tube drawing or sample. Accessory strength and bracket alignment affect real performance. |
Dimension and Installation Information
Request Drawing Before Final Installation Design
Use the dimension drawing only as a reference. Do not finalize tube cutting, bracket position or system width without model-specific drawing confirmation.
Do not finalize tube cutting, bracket position, minimum system width or installation clearance from product photos alone. Share the tube drawing, bracket structure and application size for confirmation.

Tube, Crown, Drive Wheel and Bracket Matching
Compatibility Must Be Confirmed as a System
Motor selection is only one part of the system. Real performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and installation quality.
| System Part | Compatibility Check |
|---|---|
| Tube diameter | Confirm heavy-duty 70mm+ tube profile and wall thickness. |
| Crown adaptor | Must match tube profile; do not assume one crown fits all tubes. |
| Drive wheel | Must match torque, tube profile and insertion depth. |
| Bracket | Check head style, fixing hole, load direction and installation alignment. |
| Controller / receiver | Confirm wiring, transmitter, gateway or controller compatibility when applicable. |
| Installation quality | Motor performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and side-guide friction. |
Related resources: Accessories and tube and bracket compatibility guide.
Wiring / Control / Limit Setting Notes
Confirm Control Configuration Before Installation
YYGL59S is a 59mm wired AC mechanical limit motor. Use wall switch control or a compatible external receiver. Manual override is not standard; electronic limit is not YYGL59S; obstacle detection is not standard and depends on exact control system if required.
Safety note: Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring. Ask Walter Motor for the correct wiring diagram before bulk installation.
Compare limit and control choices in the limit systems guide.
Application Review
Where YYGL59S Fits
Application fit must be checked together with load, tube, control method, environment and duty cycle.
| Application | Fit | Engineering Check |
|---|---|---|
| Roller blinds | Need confirmation | Usually over-specified; confirm tube and load. |
| Roller shutters | Yes | Confirm shutter weight, side guide friction and duty cycle. |
| Zip screens | Possible | Check fabric tension, guide friction and controller requirement. |
| Awnings | Possible | Confirm arm load, wind exposure and torque margin. |
| Garage doors / heavy shutters | Need confirmation | Requires project-specific safety devices and local compliance review. |
| Fire shutters | Not standard | Do not select without project-specific certification and safety validation. |
| Manual crank operation | Not standard | Choose manual override model if crank operation is required. |
| Electronic limit setting | Not standard | Choose electronic limit model if electronic setting is required. |
Torque Selection Guidance
Do Not Select Torque by Curtain Weight Alone
Torque selection should include curtain or fabric weight, tube diameter, lifting radius, side-guide friction, arm system or fabric tension, operating frequency, safety factor and installation environment.
Curtain or fabric weight
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Tube diameter and lifting radius
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Side guide friction
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Arm system or fabric tension
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Operating frequency
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Safety factor
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Installation environment
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Destination market requirement
Include this information in the RFQ so Walter Motor can check the model before sample or batch order.
Related guide: torque calculation for tubular motors.
OEM / ODM Options
Configuration Options for Project Buyers
Walter Motor can discuss OEM options according to target quantity, destination market and certification requirement.
Customization reference: OEM / ODM customization.
Quality Control
Quality Control for YYGL59S Series
Walter Motor controls production through incoming material inspection, stator winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.








See production process and quality control for factory-level context.
Certifications and Compliance
Certificate Coverage Must Match Exact Model and Market
Walter Motor can provide certification documents according to exact model, voltage and destination market. Commonly requested documents may include CE, LVD, EMC, RoHS and related reports. Certificate coverage must be confirmed by exact model and market.
Technical Document Request
Request Technical Documents
If PDF files are not published, these requests go to Walter Motor technical support instead of pretending to be direct downloads.
FAQ
YYGL59S Buyer Questions
What is YYGL59S best used for?
YYGL59S 59mm Heavy-Duty Motor is best used for heavy roller shutters, commercial shutters and large awnings after torque, tube and accessory matching are confirmed.
How is YYGL59S different from YYGL59R?
YYGL59S is positioned as a 59mm heavy-duty mechanical limit motor. Compare nearby models when receiver, electronic limit, short body or manual override functions are required.
What control method does YYGL59S use?
Wall switch / external receiver. Where smart integration is required, confirm the compatible gateway or controller before ordering.
Which tube is compatible with YYGL59S?
Heavy-duty tube systems should be confirmed by 70mm+ tube drawing or sample, including accessory strength and bracket alignment.
How should torque be selected for YYGL59S?
Do not select torque by curtain weight alone. Confirm curtain size, weight, tube diameter, lifting radius, guide friction, duty cycle and safety factor.
Does YYGL59S include manual override?
No. YYGL59S 59mm Heavy-Duty Motor is not the manual override model; choose a manual override model when crank operation is required.
Does YYGL59S include electronic limit or built-in receiver?
No. It uses mechanical limit setting unless a different selected variant is confirmed. No built-in receiver should be assumed. Use wall switch, external receiver or choose a receiver model if that function is required.
Can Walter Motor provide certificates and OEM options for YYGL59S?
Walter Motor can provide certificate coverage checks and OEM options according to exact model, voltage, control configuration, quantity and destination market.
RFQ Checklist
Information to Send Before Quotation
Complete information helps Walter Motor check torque, tube compatibility, control method and OEM configuration before sample or batch order.
Technical Support
Need help confirming YYGL59S compatibility?
Send your tube drawing, curtain size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.