Zhejiang Walter Tubular Motor supplier

YYGL45S 45mm Mechanical Limit Tubular Motor

YYGL45S | OEM / ODM / Distributor Supply

YYGL45S 45mm Mechanical Limit Tubular Motor

A 45mm AC mechanical limit motor for roller shutters, awnings, zip screens and outdoor shading systems where simple wired control and field-adjustable end positions are required.

Torque range10-50Nm
Rated voltage230V/50Hz standard
Optional voltage110V/60Hz on request
ProtectionIP44
Limit systemMechanical limit switch
ControlWall switch / external receiver
YYGL45S 45mm mechanical limit motor for roller shutter systems
YYGL45S mechanical limit 45mm motor for roller shutters, awnings, zip screens and OEM shading systems.

Quick Decision Table

Best For / Not Recommended For

Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.

Best For

  • Standard roller shutters
  • Awnings and zip screens
  • Outdoor shading systems
  • OEM buyers needing stable AC mechanical limit motors
  • Projects using wall switch or external receiver control

Not Recommended For

  • Narrow systems requiring very short motor length
  • Battery-powered indoor blinds
  • Projects requiring built-in smart control without an external receiver
  • Fire shutter or safety-critical systems without project-specific certification
  • Applications with very frequent operation without duty cycle confirmation

Model Positioning

Why Choose YYGL45S

YYGL45S is Walter Motor’s standard mechanical limit model in the 45mm AC series. It is suited to shutter, awning, zip screen and OEM batch projects that need a simple wired drive with mechanical end-position adjustment and easy field maintenance.

45mm series model comparison
Model Positioning When to Choose
YYGL45S Standard mechanical limit Wall switch or external receiver control with simple mechanical limit setting.
YYGL45R Mechanical limit with built-in receiver RF remote control is required inside the motor head.
YYGL45B Electronic limit / parallel control option Project control needs electronic limit logic or supported parallel wiring.
YYGL45E Electronic limit with receiver Electronic setting plus RF receiver functions are preferred.
YYGL45M Mechanical limit with manual override Manual crank operation is required during power failure.
YYGL45SD Short body design Installation width is limited and standard motor length is difficult to fit.
WM45DS DC or solar-powered solution Low-voltage, battery or solar power is required instead of mains AC.

Key Specifications

Core Procurement Parameters

Motor diameter45mm
Torque range10 / 15 / 20 / 30 / 40 / 50Nm
Rated voltage230V AC / 50Hz; 110V AC / 60Hz optional
Limit systemMechanical limit switch
Protection ratingIP44
ApplicationRoller shutters, awnings, zip screens
ControlWall switch / external receiver
OEM optionsCable length, plug, label, packaging, accessories

Technical Data

Engineering Parameters by Torque Version

The following model-specific values are taken from the current YYGL45S product data. Items not confirmed by public product data are marked for Walter Motor confirmation.

A. Electrical Data

YYGL45S electrical data
Model Torque Rated speed Voltage Frequency Rated power Rated current Running time Protection Limit turns Total length
YYGL45S-10/15 10Nm 15rpm 230V AC 50Hz 132W 0.58A 4 minutes IP44 22/42 440mm
YYGL45S-15/17 15Nm 17rpm 230V AC 50Hz 143W 0.62A 4 minutes IP44 22/42 440mm
YYGL45S-20/15 20Nm 15rpm 230V AC 50Hz 156W 0.68A 4 minutes IP44 22/42 440mm
YYGL45S-30/15 30Nm 15rpm 230V AC 50Hz 204W 0.90A 4 minutes IP44 22/42 480mm
YYGL45S-40/15 40Nm 15rpm 230V AC 50Hz 218W 0.95A 4 minutes IP44 22/42 510mm
YYGL45S-50/12 50Nm 12rpm 230V AC 50Hz 232W 1.01A 4 minutes IP44 22/42 510mm

110V/60Hz versions, insulation class and market-specific electrical documents should be confirmed according to the selected torque version.

B. Mechanical Data

Motor diameter45mm
Motor length by torque version440mm / 480mm / 510mm according to model
Suitable tube60mm and 70mm octagonal tube with matching adapters; other tubes require confirmation
Crown adaptorMatched to tube profile and inner diameter
Drive wheelMatched to tube profile, torque version and curtain load
BracketMotor head and mounting position to be confirmed by installation drawing
Motor head optionsAvailable upon request
Cable lengthStandard or custom length to be confirmed before order
Manual override availabilityNot for YYGL45S; use YYGL45M if manual crank is required

C. Application Data

Roller shutterSuitable after torque, tube and curtain weight confirmation
AwningSuitable when wind load, arm system and duty cycle are checked
Zip screenSuitable when guide friction and fabric tension are evaluated
Outdoor shadingSuitable for mains-powered systems within IP44 use conditions
Garage door / heavy shutterNeed confirmation of torque, safety and manual operation requirements

Dimension and Installation Information

Request YYGL45S Dimension Drawing Before Final Design

Dimension drawing available upon request. Do not finalize tube cutting, bracket position or minimum system width from the product photo alone.

YYGL45S motor profile for dimension drawing request
Motor overall length440mm / 480mm / 510mm by torque version
Head dimensionDimension drawing available upon request
Tube insertion depthConfirm according to tube and accessory set
Cable outlet positionConfirm by selected motor head and bracket
Bracket mounting areaConfirm with installation drawing
Minimum installation widthTo be confirmed by torque version and accessories
Request YYGL45S Dimension Drawing

Tube and Accessory Compatibility

Tube, Crown, Drive Wheel and Bracket Matching

Motor performance depends on tube diameter, curtain weight, accessory fitting, bracket alignment and installation quality. Send tube drawings or samples when the profile is not standard.

Tube Compatibility

Tube Type Compatibility Notes
60mm octagonal tube Compatible Use matching crown adaptor and drive wheel.
70mm octagonal tube Compatible Use matching crown adaptor and drive wheel.
Round tube Optional Confirm inner diameter, wall thickness and adapter availability.
Special profile tube Need confirmation Send tube drawing or sample for accessory matching.

Accessory Compatibility

Accessory Status Selection Note
Crown adaptorRequiredMatch to tube profile and motor diameter.
Drive wheelRequiredMatch to tube profile and torque version.
Motor bracketRequiredMatch to motor head and mounting structure.
End capOptionalSelect according to tube and opposite support side.
Wall switchCompatibleCommon wired control method.
External receiverCompatibleUse when remote control is required.
Remote controlWith external receiverSelect receiver and transmitter as a system.
Manual crankNot for YYGL45SUse YYGL45M if manual override is required.

Need a structured accessory check? Review the tube and bracket compatibility guide or send your tube drawing to Walter Motor.

Wiring and Limit Setting

Wired AC Control with Mechanical Limit Adjustment

  • YYGL45S is a wired AC motor with mechanical limit setting.
  • It can be controlled by wall switch or external receiver.
  • Mechanical limits are adjusted after installation according to upper and lower end positions.
  • Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring.
  • For built-in receiver, electronic limit or manual override options, compare with YYGL45R, YYGL45E, YYGL45B or YYGL45M.

Wiring diagram available upon request. For control system design, also see the limit systems guide and manual override guide.

Request Wiring Diagram

Application Review

Recommended Applications and Selection Notes

Application Suitable? Notes
Roller shutterYesConfirm shutter weight, tube diameter and friction.
AwningYesWind load and arm system must be evaluated.
Zip screenYesCheck side guide friction.
Roller blindPossibleSmaller 25mm or 35mm motors may be more suitable.
Garage door / heavy shutterNeed confirmationConfirm torque, safety and manual operation requirements.
Fire shutterNot standardRequires project-specific certification and validation.

Torque Selection Guidance

Do Not Select Torque by Curtain Weight Alone

Correct torque selection should consider the full shutter or shading system, not only the nominal fabric or curtain weight.

Buyers Should Confirm

  • Curtain or fabric weight
  • Tube diameter
  • Lifting radius
  • Friction from side guides or arms
  • Operating frequency
  • Safety factor
  • Installation environment

Need Torque Support?

Send your shutter size, weight and tube drawing to Walter Motor for torque recommendation before sample or batch order.

Send Project Data

OEM / ODM Options

Configuration for Private Label and Batch Supply

Voltage230V/50Hz, 110V/60Hz optional
Torque10-50Nm
Cable lengthCustomizable
Plug / connectorOptional, confirm destination market and wiring practice
Motor headDifferent head options available upon request
LabelWalter / Hualite / private label
PackagingNeutral or customer brand
AccessoriesCrown, drive wheel, bracket, remote, receiver
Sample orderAvailable
Batch productionAvailable for OEM customers

For OEM tubular motor supply planning, review Walter Motor customization support and the 45mm product range.

Quality Control

Quality Control for YYGL45S Series

Walter Motor controls YYGL45S production through incoming material inspection, winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.

Incoming material inspection
Stator winding inspection
Rotor and gearbox assembly control
Hi-pot test
Insulation resistance test
Torque test
Limit switch test
Noise inspection
Aging test
Final inspection before packing

Useful supporting pages: production process, quality control, patents and innovation.

Certifications and Compliance

Confirm Certificate Coverage by Exact Model and Market

Walter Motor can provide certification documents according to model and market requirements. Commonly requested documents include CE, LVD, EMC, RoHS and related test reports. Certificate coverage should be confirmed by exact model, voltage and destination market.

Downloads

Request Technical Documents

Use the links below as RFQ document requests until final PDF URLs are published.

Related Products

Compare Nearby Walter Motor Models

FAQ

YYGL45S Buyer Questions

What is the main difference between YYGL45S and YYGL45R?

YYGL45S is the standard wired mechanical limit version. YYGL45R keeps mechanical limit setting but adds a built-in receiver for RF remote control.

Can YYGL45S be used with remote control?

Yes, it can work with an external receiver and compatible transmitter. If the receiver must be built into the motor, compare YYGL45R or YYGL45E.

Is YYGL45S suitable for awnings?

Yes, it can be used for awnings after confirming torque, tube size, arm system, wind load and duty cycle requirements.

Can YYGL45S be used during a power failure?

No. YYGL45S is a mains-powered motor without manual override. Choose YYGL45M if manual crank operation is required during power failure.

How do I choose the correct torque?

Confirm curtain or fabric weight, tube diameter, lifting radius, side guide or arm friction, operating frequency and safety factor. Walter Motor can review these details before sample order.

Which tube size is compatible with YYGL45S?

Common 60mm and 70mm octagonal tubes can be matched with the proper crown adaptor and drive wheel. Round or special profile tubes should be checked by drawing or sample.

Can Walter Motor provide OEM label and packaging?

Yes. OEM options can include cable length, plug, motor label, private label packaging and matched accessories, subject to order details and confirmation.

Can I get datasheet, wiring diagram and certificates before ordering?

Yes. Buyers can request the datasheet, dimension drawing, wiring diagram, limit setting guide and certificate coverage according to the exact model, voltage and destination market.

RFQ Checklist

Information Needed for Accurate Motor Recommendation

To recommend the correct motor, please provide the following information in your inquiry.

Application
Curtain size
Curtain weight
Tube type and diameter
Required torque or current motor model
Voltage and frequency
Control method
Cable length and plug
Accessory requirement
Target quantity
Destination market and certification requirement

Technical Support

Need help confirming YYGL45S compatibility?

Send your tube drawing, shutter size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.