YYGL45S | OEM / ODM / Distributor Supply
A 45mm AC mechanical limit motor for roller shutters, awnings, zip screens and outdoor shading systems where simple wired control and field-adjustable end positions are required.
Quick Decision Table
Best For / Not Recommended For
Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.
Best For
- Standard roller shutters
- Awnings and zip screens
- Outdoor shading systems
- OEM buyers needing stable AC mechanical limit motors
- Projects using wall switch or external receiver control
Not Recommended For
- Narrow systems requiring very short motor length
- Battery-powered indoor blinds
- Projects requiring built-in smart control without an external receiver
- Fire shutter or safety-critical systems without project-specific certification
- Applications with very frequent operation without duty cycle confirmation
Model Positioning
Why Choose YYGL45S
YYGL45S is Walter Motor’s standard mechanical limit model in the 45mm AC series. It is suited to shutter, awning, zip screen and OEM batch projects that need a simple wired drive with mechanical end-position adjustment and easy field maintenance.
| Model | Positioning | When to Choose |
|---|---|---|
| YYGL45S | Standard mechanical limit | Wall switch or external receiver control with simple mechanical limit setting. |
| YYGL45R | Mechanical limit with built-in receiver | RF remote control is required inside the motor head. |
| YYGL45B | Electronic limit / parallel control option | Project control needs electronic limit logic or supported parallel wiring. |
| YYGL45E | Electronic limit with receiver | Electronic setting plus RF receiver functions are preferred. |
| YYGL45M | Mechanical limit with manual override | Manual crank operation is required during power failure. |
| YYGL45SD | Short body design | Installation width is limited and standard motor length is difficult to fit. |
| WM45DS | DC or solar-powered solution | Low-voltage, battery or solar power is required instead of mains AC. |
Key Specifications
Core Procurement Parameters
Technical Data
Engineering Parameters by Torque Version
The following model-specific values are taken from the current YYGL45S product data. Items not confirmed by public product data are marked for Walter Motor confirmation.
A. Electrical Data
| Model | Torque | Rated speed | Voltage | Frequency | Rated power | Rated current | Running time | Protection | Limit turns | Total length |
|---|---|---|---|---|---|---|---|---|---|---|
| YYGL45S-10/15 | 10Nm | 15rpm | 230V AC | 50Hz | 132W | 0.58A | 4 minutes | IP44 | 22/42 | 440mm |
| YYGL45S-15/17 | 15Nm | 17rpm | 230V AC | 50Hz | 143W | 0.62A | 4 minutes | IP44 | 22/42 | 440mm |
| YYGL45S-20/15 | 20Nm | 15rpm | 230V AC | 50Hz | 156W | 0.68A | 4 minutes | IP44 | 22/42 | 440mm |
| YYGL45S-30/15 | 30Nm | 15rpm | 230V AC | 50Hz | 204W | 0.90A | 4 minutes | IP44 | 22/42 | 480mm |
| YYGL45S-40/15 | 40Nm | 15rpm | 230V AC | 50Hz | 218W | 0.95A | 4 minutes | IP44 | 22/42 | 510mm |
| YYGL45S-50/12 | 50Nm | 12rpm | 230V AC | 50Hz | 232W | 1.01A | 4 minutes | IP44 | 22/42 | 510mm |
110V/60Hz versions, insulation class and market-specific electrical documents should be confirmed according to the selected torque version.
B. Mechanical Data
| Motor diameter | 45mm |
|---|---|
| Motor length by torque version | 440mm / 480mm / 510mm according to model |
| Suitable tube | 60mm and 70mm octagonal tube with matching adapters; other tubes require confirmation |
| Crown adaptor | Matched to tube profile and inner diameter |
| Drive wheel | Matched to tube profile, torque version and curtain load |
| Bracket | Motor head and mounting position to be confirmed by installation drawing |
| Motor head options | Available upon request |
| Cable length | Standard or custom length to be confirmed before order |
| Manual override availability | Not for YYGL45S; use YYGL45M if manual crank is required |
C. Application Data
| Roller shutter | Suitable after torque, tube and curtain weight confirmation |
|---|---|
| Awning | Suitable when wind load, arm system and duty cycle are checked |
| Zip screen | Suitable when guide friction and fabric tension are evaluated |
| Outdoor shading | Suitable for mains-powered systems within IP44 use conditions |
| Garage door / heavy shutter | Need confirmation of torque, safety and manual operation requirements |
Dimension and Installation Information
Request YYGL45S Dimension Drawing Before Final Design
Dimension drawing available upon request. Do not finalize tube cutting, bracket position or minimum system width from the product photo alone.
Tube and Accessory Compatibility
Tube, Crown, Drive Wheel and Bracket Matching
Motor performance depends on tube diameter, curtain weight, accessory fitting, bracket alignment and installation quality. Send tube drawings or samples when the profile is not standard.
Tube Compatibility
| Tube Type | Compatibility | Notes |
|---|---|---|
| 60mm octagonal tube | Compatible | Use matching crown adaptor and drive wheel. |
| 70mm octagonal tube | Compatible | Use matching crown adaptor and drive wheel. |
| Round tube | Optional | Confirm inner diameter, wall thickness and adapter availability. |
| Special profile tube | Need confirmation | Send tube drawing or sample for accessory matching. |
Accessory Compatibility
| Accessory | Status | Selection Note |
|---|---|---|
| Crown adaptor | Required | Match to tube profile and motor diameter. |
| Drive wheel | Required | Match to tube profile and torque version. |
| Motor bracket | Required | Match to motor head and mounting structure. |
| End cap | Optional | Select according to tube and opposite support side. |
| Wall switch | Compatible | Common wired control method. |
| External receiver | Compatible | Use when remote control is required. |
| Remote control | With external receiver | Select receiver and transmitter as a system. |
| Manual crank | Not for YYGL45S | Use YYGL45M if manual override is required. |
Need a structured accessory check? Review the tube and bracket compatibility guide or send your tube drawing to Walter Motor.
Wiring and Limit Setting
Wired AC Control with Mechanical Limit Adjustment
- YYGL45S is a wired AC motor with mechanical limit setting.
- It can be controlled by wall switch or external receiver.
- Mechanical limits are adjusted after installation according to upper and lower end positions.
- Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring.
- For built-in receiver, electronic limit or manual override options, compare with YYGL45R, YYGL45E, YYGL45B or YYGL45M.
Wiring diagram available upon request. For control system design, also see the limit systems guide and manual override guide.
Request Wiring DiagramApplication Review
Recommended Applications and Selection Notes
| Application | Suitable? | Notes |
|---|---|---|
| Roller shutter | Yes | Confirm shutter weight, tube diameter and friction. |
| Awning | Yes | Wind load and arm system must be evaluated. |
| Zip screen | Yes | Check side guide friction. |
| Roller blind | Possible | Smaller 25mm or 35mm motors may be more suitable. |
| Garage door / heavy shutter | Need confirmation | Confirm torque, safety and manual operation requirements. |
| Fire shutter | Not standard | Requires project-specific certification and validation. |
Torque Selection Guidance
Do Not Select Torque by Curtain Weight Alone
Correct torque selection should consider the full shutter or shading system, not only the nominal fabric or curtain weight.
Buyers Should Confirm
- Curtain or fabric weight
- Tube diameter
- Lifting radius
- Friction from side guides or arms
- Operating frequency
- Safety factor
- Installation environment
Need Torque Support?
Send your shutter size, weight and tube drawing to Walter Motor for torque recommendation before sample or batch order.
Send Project DataOEM / ODM Options
Configuration for Private Label and Batch Supply
| Voltage | 230V/50Hz, 110V/60Hz optional |
|---|---|
| Torque | 10-50Nm |
| Cable length | Customizable |
| Plug / connector | Optional, confirm destination market and wiring practice |
| Motor head | Different head options available upon request |
| Label | Walter / Hualite / private label |
| Packaging | Neutral or customer brand |
| Accessories | Crown, drive wheel, bracket, remote, receiver |
| Sample order | Available |
| Batch production | Available for OEM customers |
For OEM tubular motor supply planning, review Walter Motor customization support and the 45mm product range.
Quality Control
Quality Control for YYGL45S Series
Walter Motor controls YYGL45S production through incoming material inspection, winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.
Useful supporting pages: production process, quality control, patents and innovation.
Certifications and Compliance
Confirm Certificate Coverage by Exact Model and Market
Walter Motor can provide certification documents according to model and market requirements. Commonly requested documents include CE, LVD, EMC, RoHS and related test reports. Certificate coverage should be confirmed by exact model, voltage and destination market.
Downloads
Request Technical Documents
Use the links below as RFQ document requests until final PDF URLs are published.
Related Products
Compare Nearby Walter Motor Models
FAQ
YYGL45S Buyer Questions
What is the main difference between YYGL45S and YYGL45R?
YYGL45S is the standard wired mechanical limit version. YYGL45R keeps mechanical limit setting but adds a built-in receiver for RF remote control.
Can YYGL45S be used with remote control?
Yes, it can work with an external receiver and compatible transmitter. If the receiver must be built into the motor, compare YYGL45R or YYGL45E.
Is YYGL45S suitable for awnings?
Yes, it can be used for awnings after confirming torque, tube size, arm system, wind load and duty cycle requirements.
Can YYGL45S be used during a power failure?
No. YYGL45S is a mains-powered motor without manual override. Choose YYGL45M if manual crank operation is required during power failure.
How do I choose the correct torque?
Confirm curtain or fabric weight, tube diameter, lifting radius, side guide or arm friction, operating frequency and safety factor. Walter Motor can review these details before sample order.
Which tube size is compatible with YYGL45S?
Common 60mm and 70mm octagonal tubes can be matched with the proper crown adaptor and drive wheel. Round or special profile tubes should be checked by drawing or sample.
Can Walter Motor provide OEM label and packaging?
Yes. OEM options can include cable length, plug, motor label, private label packaging and matched accessories, subject to order details and confirmation.
Can I get datasheet, wiring diagram and certificates before ordering?
Yes. Buyers can request the datasheet, dimension drawing, wiring diagram, limit setting guide and certificate coverage according to the exact model, voltage and destination market.
RFQ Checklist
Information Needed for Accurate Motor Recommendation
To recommend the correct motor, please provide the following information in your inquiry.
Technical Support
Need help confirming YYGL45S compatibility?
Send your tube drawing, shutter size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.

