Zhejiang Walter Tubular Motor supplier

YYGL59S 59mm Mechanical Limit Motor for Heavy Shutters and Awnings

YYGL59S | OEM / ODM / Distributor Supply

YYGL59S 59mm Mechanical Limit Motor for Heavy Shutters and Awnings

YYGL59S is the heavy-duty mechanical limit model. It should not be described as standard obstacle detection, manual override or electronic limit. Choose YYGL59M or YYGL59MR for crank operation, and YYGL59E for electronic limit.

ModelYYGL59S
Diameter59mm
Torque range60-140Nm
Speed range9-15rpm
Rated voltage230V AC / 50Hz
Limit systemMechanical limit switch
Control methodWall switch / external receiver
ProtectionIP44
Best applicationHeavy roller shutters, commercial shutters and large awnings
YYGL59S 59mm mechanical limit motor for heavy roller shutters
YYGL59S 59mm mechanical limit motor for heavy roller shutters.

Product Images

YYGL59S Product View and Application Context

Product photos are used for model recognition only. Final dimensions, tube cutting and bracket positions should be confirmed by drawing.

Quick Decision Table

Best For / Not Recommended For

Use this table for first-pass purchasing review before requesting drawings, accessory confirmation or sample approval.

Best For

  • Heavy roller shutters
  • Commercial shutters
  • Large awnings
  • Heavy-duty shading systems
  • Projects needing simple wired control or external receiver

Not Recommended For

  • Standard manual override requirement
  • Electronic limit requirement
  • Standard obstacle detection claims
  • Light blinds where smaller motors are sufficient

Model Positioning

Why Choose YYGL59S

59mm standard mechanical limit AC tubular motor for heavy roller shutters, commercial shutters, large awnings and heavy-duty shading systems.

59mm same series comparison
ModelPositioningWhen to Choose
YYGL59SStandard mechanical limitHeavy shutters and large systems with wired control or external receiver.
YYGL59RMechanical limit with built-in receiverHeavy systems needing RF receiver control.
YYGL59MManual overrideCrank operation is required for heavy systems.
YYGL59MRManual override plus receiverRF control and crank operation are both required.
YYGL59EElectronic limitHeavy systems needing electronic end-position setting.

Core Procurement Parameters

YYGL59S Purchasing Specification Summary

Use this section to check the model’s main procurement boundaries before preparing an RFQ.

YYGL59S core procurement parameters
ParameterSpecification / Confirmation Note
Motor diameter59mm
Torque range60-140Nm
Rated voltage230V AC
Frequency50Hz
Limit systemMechanical limit switch
Control methodWall switch / external receiver
Protection ratingIP44
ApplicationHeavy roller shutters, commercial shutters and large awnings
OEM optionsVoltage, cable length, plug, motor head, label, packaging and matched accessories by order requirement
Accessory matching requirementTube, crown adaptor, drive wheel and bracket must be checked by drawing or sample
Certification document availabilityAvailable by exact model, voltage and destination market confirmation

Engineering Parameters by Torque Version

YYGL59S Technical Data Table

The following values use the model data supplied for this upgrade. Garbled legacy values have been separated into protection, limit type and total length where applicable.

YYGL59S electrical and mechanical data
ModelTorqueRated speedVoltageFrequencyRated powerRated currentRunning timeProtectionLimit turnsTotal length
YYGL59S-60/1560Nm15rpm230V50Hz310W1.35A4 minutesIP4422600mm
YYGL59S-80/1580Nm15rpm230V50Hz330W1.43A4 minutesIP4422600mm
YYGL59S-100/12100Nm12rpm230V50Hz350W1.52A4 minutesIP4422600mm
YYGL59S-120/9120Nm9rpm230V50Hz360W1.56A4 minutesIP4422600mm
YYGL59S-140/9140Nm9rpm230V50Hz430W1.86A4 minutesIP4422600mm

Mechanical Data

Tube, Head and Accessory Requirements

Heavy-duty tube, crown, drive wheel and bracket matching must be confirmed by 70mm+ tube drawing or sample. Accessory strength and bracket alignment affect real performance.

YYGL59S mechanical data
ItemEngineering Note
Motor diameter59mm
Total lengthSee engineering table by torque version
Tube compatibilityHeavy-duty 70mm+ tube systems; confirm tube profile and accessory strength.
Crown adaptorMatch crown profile to tube shape and inner diameter
Drive wheelConfirm drive wheel profile, torque transfer and insertion depth
BracketConfirm motor head, fixing holes, load direction and site structure
Cable lengthStandard or OEM length available on request
Motor headConfirm head style, receiver/manual override clearance and bracket fit
Accessory notesHeavy-duty tube, crown, drive wheel and bracket matching must be confirmed by 70mm+ tube drawing or sample. Accessory strength and bracket alignment affect real performance.

Dimension and Installation Information

Request Drawing Before Final Installation Design

Use the dimension drawing only as a reference. Do not finalize tube cutting, bracket position or system width without model-specific drawing confirmation.

Do not finalize tube cutting, bracket position, minimum system width or installation clearance from product photos alone. Share the tube drawing, bracket structure and application size for confirmation.

Total lengthCheck by torque version
Tube insertionConfirm by crown and drive wheel
Bracket positionConfirm by head and load direction
Cable / control clearanceConfirm before sample order
YYGL59S dimension drawing for installation confirmation
YYGL59S dimension drawing for reference; request the latest drawing before final design.

Tube, Crown, Drive Wheel and Bracket Matching

Compatibility Must Be Confirmed as a System

Motor selection is only one part of the system. Real performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and installation quality.

YYGL59S compatibility checklist
System PartCompatibility Check
Tube diameterConfirm heavy-duty 70mm+ tube profile and wall thickness.
Crown adaptorMust match tube profile; do not assume one crown fits all tubes.
Drive wheelMust match torque, tube profile and insertion depth.
BracketCheck head style, fixing hole, load direction and installation alignment.
Controller / receiverConfirm wiring, transmitter, gateway or controller compatibility when applicable.
Installation qualityMotor performance depends on tube diameter, curtain weight, accessory fit, bracket alignment and side-guide friction.

Related resources: Accessories and tube and bracket compatibility guide.

Wiring / Control / Limit Setting Notes

Confirm Control Configuration Before Installation

YYGL59S is a 59mm wired AC mechanical limit motor. Use wall switch control or a compatible external receiver. Manual override is not standard; electronic limit is not YYGL59S; obstacle detection is not standard and depends on exact control system if required.

Safety note: Do not connect multiple standard motors in parallel unless the selected model and control system support parallel wiring. Ask Walter Motor for the correct wiring diagram before bulk installation.

Compare limit and control choices in the limit systems guide.

Application Review

Where YYGL59S Fits

Application fit must be checked together with load, tube, control method, environment and duty cycle.

YYGL59S application review
ApplicationFitEngineering Check
Roller blindsNeed confirmationUsually over-specified; confirm tube and load.
Roller shuttersYesConfirm shutter weight, side guide friction and duty cycle.
Zip screensPossibleCheck fabric tension, guide friction and controller requirement.
AwningsPossibleConfirm arm load, wind exposure and torque margin.
Garage doors / heavy shuttersNeed confirmationRequires project-specific safety devices and local compliance review.
Fire shuttersNot standardDo not select without project-specific certification and safety validation.
Manual crank operationNot standardChoose manual override model if crank operation is required.
Electronic limit settingNot standardChoose electronic limit model if electronic setting is required.

Torque Selection Guidance

Do Not Select Torque by Curtain Weight Alone

Torque selection should include curtain or fabric weight, tube diameter, lifting radius, side-guide friction, arm system or fabric tension, operating frequency, safety factor and installation environment.

Curtain or fabric weight

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Tube diameter and lifting radius

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Side guide friction

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Arm system or fabric tension

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Operating frequency

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Safety factor

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Installation environment

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Destination market requirement

Include this information in the RFQ so Walter Motor can check the model before sample or batch order.

Related guide: torque calculation for tubular motors.

OEM / ODM Options

Configuration Options for Project Buyers

Walter Motor can discuss OEM options according to target quantity, destination market and certification requirement.

Voltage
Torque
Cable length
Plug / connector
Motor head
Label
Packaging
Crown adaptor
Drive wheel
Bracket
Remote / receiver / controller if applicable
Sample order
Batch production

Customization reference: OEM / ODM customization.

Quality Control

Quality Control for YYGL59S Series

Walter Motor controls production through incoming material inspection, stator winding inspection, rotor and gearbox assembly control, hi-pot testing, insulation resistance testing, torque testing, limit switch testing, noise inspection, aging test and final inspection before packing.

See production process and quality control for factory-level context.

Certifications and Compliance

Certificate Coverage Must Match Exact Model and Market

Walter Motor can provide certification documents according to exact model, voltage and destination market. Commonly requested documents may include CE, LVD, EMC, RoHS and related reports. Certificate coverage must be confirmed by exact model and market.

Request Certificate Coverage View certificate page

Technical Document Request

Request Technical Documents

If PDF files are not published, these requests go to Walter Motor technical support instead of pretending to be direct downloads.

FAQ

YYGL59S Buyer Questions

What is YYGL59S best used for?

YYGL59S 59mm Heavy-Duty Motor is best used for heavy roller shutters, commercial shutters and large awnings after torque, tube and accessory matching are confirmed.

How is YYGL59S different from YYGL59R?

YYGL59S is positioned as a 59mm heavy-duty mechanical limit motor. Compare nearby models when receiver, electronic limit, short body or manual override functions are required.

What control method does YYGL59S use?

Wall switch / external receiver. Where smart integration is required, confirm the compatible gateway or controller before ordering.

Which tube is compatible with YYGL59S?

Heavy-duty tube systems should be confirmed by 70mm+ tube drawing or sample, including accessory strength and bracket alignment.

How should torque be selected for YYGL59S?

Do not select torque by curtain weight alone. Confirm curtain size, weight, tube diameter, lifting radius, guide friction, duty cycle and safety factor.

Does YYGL59S include manual override?

No. YYGL59S 59mm Heavy-Duty Motor is not the manual override model; choose a manual override model when crank operation is required.

Does YYGL59S include electronic limit or built-in receiver?

No. It uses mechanical limit setting unless a different selected variant is confirmed. No built-in receiver should be assumed. Use wall switch, external receiver or choose a receiver model if that function is required.

Can Walter Motor provide certificates and OEM options for YYGL59S?

Walter Motor can provide certificate coverage checks and OEM options according to exact model, voltage, control configuration, quantity and destination market.

RFQ Checklist

Information to Send Before Quotation

Complete information helps Walter Motor check torque, tube compatibility, control method and OEM configuration before sample or batch order.

Application
Curtain size
Curtain weight
Tube type and diameter
Required torque or current motor model
Voltage and frequency
Control method
Limit system
Cable length and plug
Accessory requirement
Target quantity
Destination market and certification requirement

Technical Support

Need help confirming YYGL59S compatibility?

Send your tube drawing, curtain size, application and target quantity. Walter Motor can help check torque, tube compatibility, control method and OEM configuration before sample or batch order.